Gauging station : ウィキペディア英語版
Stream gauge

A stream gauge, streamgage or gauging station is a location used by hydrologists or environmental scientists to monitor and test terrestrial bodies of water. Hydrometric measurements of water level surface elevation ("stage") and/or volumetric discharge (flow) are generally taken and observations of biota and water quality may also be made. The location of gauging stations are often found on topographical maps. Some gauging stations are highly automated and may include telemetry capability transmitted to a central data logging facility.
==Measurement of discharge==

Automated direct measurement of streamflow discharge is difficult at present. In place of the direct measurement of streamflow discharge, one or more surrogate measurements can be used to produce discharge values. In the majority of cases, a stage (the elevation of the water surface) measurement is used as the surrogate. Low gradient (or shallow-sloped) streams are highly influenced by variable downstream channel conditions. For these streams, a second stream gauge would be installed, and the slope of the water surface would be calculated between the gauges. This value would be used along with the stage measurement to more accurately determine the streamflow discharge. Within the last ten years, the technological advance of velocity sensors has allowed the use of water velocity as a reliable surrogate for streamflow discharge at sites with a stable cross-sectional area. These sensors are permanently mounted in the stream and measure velocity at a particular location in the stream and related to flow in a manner similar to the use of traditional water level.
In those instances where only a stage measurement is used as the surrogate, a rating curve must be constructed. A rating curve is the functional relation between stage and discharge. It is determined by making repeated discrete measurements of streamflow discharge using a velocimeter and some means to measure the channel geometry to determine the cross-sectional area of the channel. The technicians and hydrologists responsible for determining the rating curve visit the site routinely, with special trips to measure the hydrologic extremes (floods and droughts), and make a discharge measurement by following an explicit set of instructions.
Once the rating curve is established, it can be used in conjunction with stage measurements to determine the volumetric streamflow discharge. This record then serves as an assessment of the volume of water that passes by the stream gauge and is useful for many tasks associated with hydrology.
In those instances where a velocity measurement is additionally used as a surrogate, an index velocity determination is conducted. This analysis uses a velocity sensor, often either magnetic or acoustic, to measure the velocity of the flow at a particular location in the stream cross section. Once again, discrete measurements of streamflow discharge are made by the technician or hydrologist at a variety of stages. For each discrete determination of streamflow discharge, the mean velocity of the cross section is determined by dividing streamflow discharge by the cross-sectional area. A rating curve, similar to that used for stage-discharge determinations, is constructed using the mean velocity and the index velocity from the permanently mounted meter. An additional rating curve is constructed that relates stage of the stream to cross-sectional area. Using these two ratings, the automatically collected stage produces an estimate of the cross-sectional area, and the automatically collected index velocity produces an estimate of the mean velocity of the cross section. The streamflow discharge is computed as the estimate of the cross section area and the estimate of the mean velocity of the streamflow.

抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)
ウィキペディアで「Stream gauge」の詳細全文を読む